The Measuring Method for Capacitance and Dielectric Loss of Bushing C2 after Installation |
Liu Xuemin,Su Haiqin |
Baoding Tianwei Baobian Electric Co., Ltd, Baoding, Hebei 071056 |
|
|
Abstract Capacitance and dielectric loss measuring can effectively detect the insulation flaw of electric equipment. There is some solid and oil-paper insulation between the test terminal and flange of the bushing, so it is very necessary to measure this capacitance and dielectric loss. After installation the capacitance C2 of bushing test terminal is connected to the capacitance C1 of bushing and the transformer. This paper sets up a new measuring circuit with dielectric loss measuring equipment which has a shield terminal, and the capacitance and dielectric loss of bushing C2 can be measured accurately.
|
Published: 04 November 2014
|
|
|
|
Cite this article: |
Liu Xuemin,Su Haiqin. The Measuring Method for Capacitance and Dielectric Loss of Bushing C2 after Installation[J]. Electrical Engineering, 2014, 15(07): 72-74.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2014/V15/I07/72
|
[1] 胡启凡. 变压器试验技术[M]. 北京: 中国电力出版社, 2009: 61-67. [2] 王毅, 孙强, 庄会梅, 等. 新型电容型高压设备及其末屏介损的现场试验[J]. 高电压技术,2007(4): 183-185. [3] 张小娟, 黄永清, 贺胜强. 110kV变压器套管介损试验方法[J]. 国外电子元器件, 2008(10): 87-88. |
|
|
|