电气技术  2016, Vol. 17 Issue (3): 111-115    DOI:
技术与应用 |
基于±500kV牛寨换流站GIS设备安全措施布置与研究
曹显武, 周亚树, 王电处, 刘百爽
中国南方电网超高压输电公司曲靖局,云南 曲靖 655000
Based on ± 500kV GIS Equipment Safety of Niuzhai Converter Station Measures Design and Research
Cao Xianwu, Zhou Yashu, Wang Dianchu, Liu Baishuang
Qujing Bureau, CSG EHV Transmission Company, Qujing, Yunnan 655000
全文: PDF (374 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 结合牛寨换流站现有的3/2接线的GIS一体设备,研究不同接线方式下的GIS设备检修作业时停电,验电,接地,悬挂标示牌和装设遮栏等保证作业安全的措施如何布置才能达到作业安全,停电范围最小,人机功效最佳且简单,方便,实用,有效.通过规范一,二次设备操作,确定间接验电措施,优化标识牌及遮拦布置,显化现场安全风险,最终实现GIS设备检修标准化安措布置.将研究成果应用牛寨换流站内的其他设备,并通过现场实践与验证不断进行完善后,将其推广至其他换流站或变电站,最终达到该套安全措施布置的方法适用于大多数的停电检修设备的目的.
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
曹显武
周亚树
王电处
刘百爽
关键词 GIS设备安全措施工作票安全    
Abstract:Combined Niuzhai converter station 3/2 wiring GIS equipment, The study of GIS equipment maintenance operations under different wiring, electrical inspection, grounding, job security measures and the installation of hanging nameplate cover fences guarantee how to achieve job security arrangement, the power range minimum, optimum ergonomics and simple, convenient and practical and effective. By standardizing device operations to determine indirect electrical inspection measures to optimize the signage and masking arrangement, which was the scene of a security risk, and ultimately standardize safety measures design. After the application of research results niu zhai for other equipment flow inside the station, and through field practice and verify continuous improvement, which was extended to other converter station or substation, and ultimately achieve the set of safety measures arranged method can be applied to different commutation station, substation equipment different wiring maintenance purposes.
Key wordsGIS equipment    safety measures    working votes    safety   
     出版日期: 2016-03-22
作者简介: 曹显武(1988-),男,云南楚雄市人,本科,工程师,主要从事换流站变电运行及维护工作.
引用本文:   
曹显武, 周亚树, 王电处, 刘百爽. 基于±500kV牛寨换流站GIS设备安全措施布置与研究[J]. 电气技术, 2016, 17(3): 111-115. Cao Xianwu, Zhou Yashu, Wang Dianchu, Liu Baishuang. Based on ± 500kV GIS Equipment Safety of Niuzhai Converter Station Measures Design and Research. Electrical Engineering, 2016, 17(3): 111-115.
链接本文:  
https://dqjs.cesmedia.cn/CN/Y2016/V17/I3/111