Electrical Engineering  2020, Vol. 21 Issue (6): 69-72    DOI:
Maintenance & Fault Diagnosis of Electrical Equipment Current Issue| Next Issue| Archive| Adv Search |
Analysis of excitation current in DC-biased transformer by wavelet transform
Zhou Zhihao
State Grid Jibei Electric Power Co., Ltd, Langfang Power Supply Company, Langfang, Hebei 065000

Download: PDF (10691 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  To analyze the excitation current in DC-biased transformer in depth, the thesis deduces the mathematical expression of distortion excitation current, and determines the time slot in one cycle when the exciting current distorting happens. Meanwhile, we can put forward the analysis method with wavelet transform principle, which directs at analyzing the boundedness of distortion excitation current using the Fourier transform. Through sampling the distortion excitation current signal under different DC current, we resolve its wavelet LF approximation signal and HF detail signal, conclude DC component size of the distortion excitation current, moreover, confirm the moment of excitation current waveform distorting, comparatively analyze the results after Fourier transform, and make clear that the principle is feasibility and superiority.
Key wordstransformer      DC magnetic bias      excitation current      wavelet transform      DC component      distortion time     
Received: 15 January 2020     
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
Zhou Zhihao
Cite this article:   
Zhou Zhihao. Analysis of excitation current in DC-biased transformer by wavelet transform[J]. Electrical Engineering, 2020, 21(6): 69-72.
URL:  
https://dqjs.cesmedia.cn/EN/Y2020/V21/I6/69
Copyright © Electrical Engineering
Supported by: Beijing Magtech