Electrical Engineering  2020, Vol. 21 Issue (7): 120-124    DOI:
Technology & Application Current Issue| Next Issue| Archive| Adv Search |
Analysis and improvement of radiation emission exceeding standard caused by damage of cable shield
Wang Jianchao
Jinyang Lake Management Office, Taiyuan 030021

Download: PDF (18137 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  Though the analysis of the result of the EMI test, this paper find that the reason for the radiation emission exceeding the limit is the damaged shield of communication cable, which leads to the leakage of high order harmonics of the signal. Through the rectification of the communication cable, the radiation emission of the quipment finaly meet the CCS standard.
Key wordsjacking control system      electromagnetic compatibility (EMC)      electromagnetic inter- ference (EMI)      radiated emission      offshore equipment      shielding     
Received: 31 December 2019     
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
Wang Jianchao
Cite this article:   
Wang Jianchao. Analysis and improvement of radiation emission exceeding standard caused by damage of cable shield[J]. Electrical Engineering, 2020, 21(7): 120-124.
URL:  
https://dqjs.cesmedia.cn/EN/Y2020/V21/I7/120
Copyright © Electrical Engineering
Supported by: Beijing Magtech