Research on dual inverter redundancy switching technology for circulating water pumps in nuclear power plants |
WANG Xiankun1, WU Xing1, SONG Wenke1, LI Biao1, ZHU Wei2 |
1. Shandong Nuclear Power Co., Ltd, Haiyang, Shandong 265116; 2. Shanghai Nancal Electric Co., Ltd, Shanghai 201413 |
|
|
Abstract As the core electric drive for the primary pump motor in a nuclear power plant, any fault of the frequency converter can cause extremely serious consequences for production and related processes. This paper presents a redundant drive scheme for inverters. Two inverters are used to drive one motor to provide redundant backup for the whole inverter. When the main inverter device driving the motor fails, it can automatically switch to the backup inverter drive output in a short time (within 150ms) to ensure that the motor can run continuously and stably. This dual-machine redundant switching scheme provides an important guarantee for the stable operation of the nuclear power plant and reduces potential risks.
|
Received: 22 August 2023
|
|
|
|
Cite this article: |
WANG Xiankun,WU Xing,SONG Wenke等. Research on dual inverter redundancy switching technology for circulating water pumps in nuclear power plants[J]. Electrical Engineering, 2023, 24(11): 76-80.
|
|
|
|
URL: |
https://dqjs.cesmedia.cn/EN/Y2023/V24/I11/76
|
[1] 万玉晶, 王声学, 尚一凡, 等. 浅谈大功率高压变频器在核电厂循环水系统中的首次应用[J]. 中国设备工程, 2023(增刊1): 178-180. [2] 周彬, 王云龙, 郝鹏超, 等. 高压变频器研究与应用[J]. 建筑电气, 2023, 42(4): 58-61. [3] 张军梁, 王兴. 双变频器热备切换应用技术的研究[J]. 石油化工自动化, 2018, 54(1): 35-40. [4] 徐甫荣. 变频器同步切换控制技术[J]. 电工技术, 2002(8): 37-38. [5] 刘章龙, 赵徐成, 许华, 等. 基于异步变频调制算法的UPS数字输出锁相技术[J]. 计算机与数字工程, 2016, 44(10): 1895-1898. [6] 刘军, 王立志. 变频器冗余系统的设计与应用[J]. 电气开关, 2010, 48(6): 62-63. [7] 孙康康. 高压大容量静止变频器的换流方式探讨[J].自动化应用, 2023, 64(3): 83-85. [8] 李杰, 李华奎. 一种适用于变频器电源切换装置的合闸方法[J]. 电气技术, 2022, 23(2): 105-108. [9] 王万丁, 宋向金, 陈前, 等. 采用整流技术的变频供电感应电机转子断条故障诊断方法[J]. 电工技术学报, 2022, 37(16): 4074-4083. [10] 王宪坤. AP1000核电站主泵的电气系统分析[J]. 中国核电, 2012, 5(3): 209-213. |
|
|
|