| Analysis on vibration characteristics of typical mechanical loosening faults in generator circuit breakers |
| ZHANG Mi, ZHANG Wei |
| Xi'an XD Switchgear Electric Co., Ltd, Xi'an 710077 |
|
|
|
|
Abstract To explore the vibration characteristics of mechanical loosening faults in generator circuit breakers, this paper constructs a model using the three-dimensional finite element method. It simulates and analyzes the vibration responses under normal and typical mechanical loosening faults (threaded connections loosening, pin shafts disengagement), and verifies the results by comparing them with actual measurement data. The results show that under different operating conditions, the natural frequencies of the circuit breaker are densely distributed, with the first 100 orders all within 100 Hz; loose threaded connections and loose pin shafts, as local abnormalities, have no significant impact on the natural frequencies and mode shapes of most modes, but only change some orders (or local) modes or generate new modes; the acceleration response trend under abnormal conditions is basically consistent with that under normal conditions, however, the acceleration value at 590 Hz increases significantly under the condition of loose threaded connections, and some peaks shift under the condition of loose pin shafts. The results of this study can provide a theoretical basis and reference for vibration monitoring, fault diagnosis, operation and maintenance during the operation of the equipment.
|
|
Received: 23 July 2025
|
|
|
|
| Cite this article: |
|
ZHANG Mi,ZHANG Wei. Analysis on vibration characteristics of typical mechanical loosening faults in generator circuit breakers[J]. Electrical Engineering, 2025, 26(12): 41-45.
|
|
|
|
| URL: |
|
https://dqjs.cesmedia.cn/EN/Y2025/V26/I12/41
|
[1] 费翔, 张国跃, 马明乐, 等. 大容量发电机出口真空灭弧室研制[J]. 高电压技术, 2022, 48(11): 4488-4496. [2] 邱荣. 发电机出口断路器无法正常合闸故障分析[J].化学工程与装备, 2023(12): 172-176. [3] 王灵, 王波. 抽水蓄能电站机组振动监测与分析[J].华北科技学院学报, 2023, 20(3): 65-71. [4] 李宜. 某水轮发电机出口断路器操动机构故障原因分析[J]. 电气技术, 2025, 26(4): 61-64, 72. [5] 赵书涛, 许文杰, 刘会兰, 等. 基于振动信号谱形状熵特征的高压断路器操动状态辨识方法[J]. 电工技术学报, 2022, 37(9): 2170-2178. [6] 王青华, 杨天海, 沈润杰, 等. 抽水蓄能机组振动故障诊断专家系统[J]. 振动与冲击, 2012, 31(7): 158-161. [7] 刘会兰, 许文杰, 赵书涛, 等. 面向高压断路器故障分类的电流-振动信号类聚几何敏感特征优选方法[J]. 电工技术学报, 2023, 38(1): 26-36. [8] 张永会, 乔木, 鲍峰, 等. 白山抽水蓄能电站暂态工况下机组振动特性研究[J]. 水电站机电技术, 2021, 44(3): 8-10. [9] 杨秋玉, 阮江军, 庄志坚, 等. 高压断路器机械振动信号的参数自适应降噪方法[J]. 高电压技术, 2021, 47(12): 4274-4287. [10] 陈鹤冲, 陈轩恕, 刘波, 等. 一种发电机保护用断路器布置方案的动稳定校核及仿真分析[J]. 高压电器, 2020, 56(7): 86-93. [11] 范兴明, 许洪华, 张思舜, 等. 基于改进蜣螂优化算法深度混合核极限学习机的高压断路器故障诊断[J]. 电工技术学报, 2025, 40(12): 3994-4003. |
|
|
|