| Accident analysis of opposite-side line trip caused by no-load energization of a 220 kV main transformer |
| ZENG Jingjing1, QI Zhenyu2 |
1. Nanjing Power Supply Company, State Grid Jiangsu Electric Power Co., Ltd, Nanjing 210019; 2. Extra-High Voltage Branch, State Grid Jiangsu Electric Power Co., Ltd, Nanjing 211100 |
|
|
|
|
Abstract This paper presents an accident where the line protection at the opposite substation operated and tripped as a result of the magnetizing inrush current generated during no-load energization of a 220 kV main transformer. The cause of the protection operation is identified through analysis of protection device reports, fault recorder waveforms and the characteristics of the transformer magnetizing inrush current, in conjunction with the operating conditions of the primary system and relevant transformer parameters. In response to such typical faults, targeted preventive recommendations are proposed to mitigate the impact of main transformer magnetizing inrush current on line protection, so as to enhance the operational stability of the power grid during the commissioning or reinstatement of main transformers.
|
|
Received: 23 April 2026
|
|
|
|
| Cite this article: |
|
ZENG Jingjing,QI Zhenyu. Accident analysis of opposite-side line trip caused by no-load energization of a 220 kV main transformer[J]. Electrical Engineering, 2026, 27(9): 78-84.
|
|
|
|
| URL: |
|
https://dqjs.cesmedia.cn/EN/Y2026/V27/I9/78
|
[1] 谭靖, 肖浩, 李艳, 等. 基于暂态仿真的主变涌流对线路零序过流保护的影响研究[J]. 电力系统保护与控制, 2015, 43(19): 149-153. [2] 李晓华, 罗龙波, 谢金泉, 等. 高压内置型高阻抗变压器涌流特性对保护的影响[J]. 电力系统自动化, 2016, 40(11): 108-114. [3] 龚振, 刘承锡, 姚良忠, 等. 基于增广动态相量法的变压器励磁涌流频率自适应仿真[J]. 电工技术学报, 2022, 37(15): 3805-3817. [4] 尹项根, 曹文斌, 潘远林, 等. 高阻抗电力变压器涌流特性及其对保护影响的研究[J]. 电力系统保护与控制, 2018, 46(20): 1-11. [5] 张雪松, 何奔腾. 变压器和应涌流对继电保护影响的分析[J]. 中国电机工程学报, 2006, 26(14): 12-17. [6] 王婵媛, 孔茗. PST—1200U差动保护励磁涌流判据失效原因分析及改进[J]. 电气技术, 2024, 25(11): 81-84. [7] 肖硕霜, 晋龙兴, 王世祥. 基于幅值积分比较闭锁的线路零序IV段保护方法[J]. 电气技术, 2020, 21(2): 56-59. [8] 曹文斌. 高阻抗变压器涌流特性及其对保护的影响机理和对策研究[D]. 武汉: 华中科技大学, 2020. [9] 尹项根, 张哲, 王友怀, 等. 变压器间及其与电流互感器暂态交互作用分析和保护对策[J]. 电力系统保护与控制, 2016, 44(23): 1-9. [10] 郭倩雯, 刘宇, 卢学容, 等. 自适应涌流抑制技术在高压内置结构高阻抗变压器投切中的应用[J]. 电工技术, 2019(11): 29-32, 36. [11] 武万才, 边疆, 吴志勇. 变压器和应涌流产生机理及其特性分析[J]. 电力自动化设备, 2011, 31(6): 112-115. [12] 王阳光, 尹项根, 游大海, 等. 影响变压器和应涌流的各种因素[J]. 电工技术学报, 2009, 24(9): 78-85, 106. |
|
|
|