About the Fault Analysis of Hoisting Mechanism Braking Distance Exceeds the Normal Length |
Chong Fayou |
Equipment Maintenance Plant of Wisco, Wuhan 430080 |
|
|
Abstract Factory overhead traveling crane hoisting mechanism using stator voltage control device, in this kind of control mode, when back to zero position,the braking distance of hoisting mechanism occasionally exceeds the normal length, this phenomenon brings a great security risk to the lifting operation, however, the occurrence of this fault, the associated control equipment has no any alarmings and faults, which brings great difficulties to the failure investigation. In this paper through in-depth research on equipment operation principle, searching and analyzing the root causes of the equipment brake distance, guarantee the safe operation of production.
|
Published: 05 November 2014
|
|
|
|
Cite this article: |
Chong Fayou. About the Fault Analysis of Hoisting Mechanism Braking Distance Exceeds the Normal Length[J]. Electrical Engineering, 2014, 15(09): 103-104.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2014/V15/I09/103
|
[1] 佟纯厚. 近代交流调速[M]. 北京:冶金工业出版社, 2006: 5-19. [2] 许期英. 交流调速技术与系统[M]. 北京:化学工业出版社, 2010: 15-30. |
|
|
|