The Study on FCB Test of a 660MW Domestic Supercritical Unit |
Gao Xianpeng1, Zou Baochan2, Liu Xinlong2 |
1. Datang Binchang Power Generation Co., Ltd, Shaanxi Xianyang 713602; 2. North China Electric Power Research Institute(Xi'an) Co., Ltd, Xi'an 710065; 3. Northwest Electric Power Design Institute, Xi’an 710065 |
|
|
Abstract In this paper, the control of the thermal power unit to realize the FCB function difficulty were analyzed, and on the base of this, the FCB control logic was improved and optimized. Test listed in this paper, logic design and the optimization improvement is effective. Finally, testing process parameters were provided by authors as reference for the same type unit.
|
Published: 05 November 2014
|
|
|
|
Cite this article: |
Gao Xianpeng,Zou Baochan,Liu Xinlong. The Study on FCB Test of a 660MW Domestic Supercritical Unit[J]. Electrical Engineering, 2014, 15(09): 48-52.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2014/V15/I09/48
|
[1] 刘麒,刘麟. FCB功能相关的发变组保护逻辑改造[1] [J]. 电力系统保护与控制, 2011, 39(4): 146-154. [2] 阚伟民,蔡笋,谢诞梅, 等. 超超临界1000MW机组甩负荷试验研究[J]. 热力发电, 2011, 40(5): 73-80. [3] 罗志浩,尹峰,陈小强, 等. 国产600MW超临界直流机组实现FCB功能的可行性研究[J]. 浙江电力, 2009(1): 16-44. [4] 陈小强,罗志浩. 超超临界1000MW机组RB控制策略分析及优化[J]. 热力发电, 2011, 39(7): 72-74. [5] 宁继红. 1000MW火电机组FCB功能与系统配置探讨[J]. 广西电力, 2009(4): 63-67. |
|
|
|