Development of a New Type Current Transformer Polarity Tester |
Wu Qiong1,Ning Guoli1,Wang Zhiyuan1,Deng Zhiyang2,Wang Tianhui2 |
1. Chengnan Branch of Tianjin Electric Power Corporation, Tianjin 300201; 2. Wuhan Haomai Electric Power Automation Co., Ltd, Wuhan 430223 |
|
|
Abstract Current transformer is one of the key equipment of electric energy conversion, its accuracy will Influence relay protection. Traditional current transformer polarity test has the problem of complex method, long time and low efficiency. This paper designs a new type current transformer polarity tester, which can realize the synchronous switch by wireless communication. The test shows that this tester has the advantage of high accuracy, simple operation and wide application.
|
Published: 28 September 2015
|
|
|
|
Cite this article: |
Wu Qiong,Ning Guoli,Wang Zhiyuan等. Development of a New Type Current Transformer Polarity Tester[J]. Electrical Engineering, 2015, 16(9): 86-88.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2015/V16/I9/86
|
[1] 马锃曌. 电流互感器接线和二次阻抗对继电保护可靠性影响[J]. 电力学报, 2007, 22(4): 468-470, 474. [2] 王怡. 怎样测量电流互感器的极性[J]. 农村电气化, 2003(5): 38. [3] 卢迪勇. 主变一次通流校验电流互感器二次极性[J]. 变压器, 2012, 49(3): 64-66. [4] 寿挺. 一种新型的电流互感器极性测试仪的研制[J]. 制冷空调与电力机械, 2008, 29(4): 86-87. [5] 郑杰文. 新型电流互感器极性测试装置的研制[J]. 科技传播, 2013(1): 49. [6] 马利人, 刘建华, 李帆. 电流互感器减极性和相量图常见疑惑辨析[J]. 仪表技术, 2014(3): 12-14. [7] JB/T 5356—2002. 电流互感器试验导则[S]. |
|
|
|