Control Analysis of Quick Close of Regulating Valve for Supercritical Unit |
Li Qianmin |
Guizhou Electric Power Testing & Research Institute, Guiyang 550002 |
|
|
Abstract This paper describes the research situation and technical difficulty of quick close control for intermediate regulating valve, analysises the repeatly quick close for intermediate regulating valve of 600MW. In this case, the quick clost protection reached five times,which cause fluctuation of power and the shut down of 600MW unit at last. This paper anlysises the reasones of the case, and put forward prevention measures. Improving the reliability of protectiona nd promoting safty stable operation of power grid.
|
Published: 23 May 2017
|
|
|
|
[1] 许锐锋. 西门子汽轮机调门快关问题分析[J]. 华电技术, 2014, 36(10): 51-53. [2] 陈宗金, 姜宪珍, 苑举伟, 等. 300MW机组中调门快关控制分析[J]. 电力建设, 2006, 27(2): 18-21. [3] 王会. 西门子1000MW汽轮机DEH控制逻辑优化[J]. 中国电力, 2014, 47(9): 29-33. [4] 蒙定中. 沙角C厂2号汽轮发电机组的快关试验[J]. 电网技术, 1999, 23(12): 11-15. [5] 张厚生. 快速控制中间再热机组调门的动态模拟[J]. 电力技术通讯, 1980(6): 4-8. [6] 于达仁, 赵宏, 武国贤, 等. 600MW汽轮发电机组甩 负荷计算[J]. 汽轮机技术, 1996, 38(2): 99-102. [7] 胡洲. 采用高压缸启动方式机组OPC功能试验研究[J]. 热力发电, 2013, 42(9): 81-86. [8] 王远辉, 柏毅辉. 某300MW火电机组甩负荷OPC异常动作原因分析及防止对策[C]//贵州省电机工程学会2007年优秀论文集, 2007: 188-191. |
|
|
|