Abstract Converter valve low voltage energization test is the group simulation experiment of the converter transformer, converter valve, control and protection system. Also, it had to be done before the converter station system test. Illustrated by the example of UHV Jinhua converter station, this paper details the parameter selection and the method of the converter valve low voltage energization test, propose a new way to verify the trigger angle, all of this research has important practical application of significance.
|
Published: 20 April 2015
|
|
|
|
[1] Q/GDW_264—2009《±800kV直流输电工程换流站电气二次设备交接验收试验规程》常浩, 康健, 陶瑜等. 国家电网公司. [2] 赵畹君. 高压直流输电工程技术[M]. 2版. 北京: 中国电力出版社, 2010. [3] 郭磊, 寇晓适, 王君亮, 等. 高压直流换流阀低压加压试验的实际应用[J]. 河南电力, 2010(3): 25-27. [4] 丁一工, 康健, 金涛. 高压直流换流阀的低压加压试验研究[J]. 湖北电力, 2003, 27(12). [5] 朱奕帆, 鲍伟, 高继鸣. ±800kV特高压直流输电换流阀组低压加压试验方法探讨和应用[J]. 华东电力, 2010, 38(11): 1717-1720. |
|
|
|