Abstract Arc was generated to cause the dielectric oil polluted in the process of on-load voltage regulation which using traditional mechanical on-load tap-changer. A new scheme of arcless on load voltage regulation is needed to be developed to solve the above problems. In this paper, a new scheme of arcless on load voltage regulation is put forward based on the relative technology experiences. The regulating process of the new solution was introduced, and the PSCAD simulation model was established to give the waveform. The Regulating process of the new scheme of arcless on load voltage regulation is arcless and reliable by theoretical and data analysis.
|
Published: 28 October 2015
|
|
|
|
[1] 王福兴. 新型无弧有载分接开关研制的可能性[J]. 电网技术, 1997, 21(7): 54-57. [2] 张德明. 有载分接开关国内现状及其发展动向[J]. 变压器, 2000, 37(1): 36-39. [3] 赵刚, 施围. 无弧有载分接开关的研究[J]. 高电压技术, 2004, 30(4): 49-51. [4] Faiz J, Siahkolah B. New Solid-State on-Load Tap-Changer topology for distribution transformers[J]. Power Engineering Review, IEEE, 2002, 22(8): 71-71. [5] 张品秀. 基于晶闸管的有载自动调压分接开关的研究[D]. 哈尔滨: 东北农业大学, 2009. [6] 苏泽光, 李劲松, 徐祖华. 基于电力电子技术新型分接开关的发展[J]. 电气应用, 2005, 24(4): 43-46. |
|
|
|