Abstract Various neutral point overvoltage which may occur in the isolated neutral system transformer were presented in this paper, and the installation of neutral point arrester can keep the device from destroying. Whether the arrester is selected correctly or not is directly related to the normal system operation. The selection principle of the transformer neutral point arrester and the precautions of the maintenance process were proposed through the analysis of the breakdown of the transformer neutral point arrester caused by the line grounding fault and the finding of the fault location.
|
Received: 14 August 2018
Published: 19 March 2019
|
|
|
|
Cite this article: |
Zhang Xiongqing,Wan Fangpei,Yang Shan等. Failure analysis of the neutral point arrester of the 35kV transformer[J]. Electrical Engineering, 2019, 20(3): 115-117.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2019/V20/I3/115
|
[1] 秦家远, 阮江军. 变压器中性点过电压保护综述[J]. 华中电力, 2006, 19(1): 17-20. [2] 魏莉, 郑涛, 彭建宁, 等. 单相接地引起中性点间隙击穿后主变高压侧三相电流特点初步研究[J]. 电力系统保护与控制, 2010, 38(8): 140-143. [3] 刘剑, 邰能灵, 范春菊, 等. 基于特定频率电流波形特征的高压直流线路故障判别方法[J]. 电工技术学报, 2017, 32(1): 20-31. [4] 马晓文, 王泽学, 张伟佳, 等. 变电站的施工管理及其控制[J]. 电气技术, 2016, 17(2): 127-129, 138. [5] 鲍永胜, 郝峰杰, 徐建忠, 等. GIS局部放电脉冲分类特征提取算法[J]. 电工技术学报, 2016, 31(9): 181-188. [6] 刘涵, 毛学锋, 吴毅. 氧化锌避雷器带电检测方法及现场故障分析[J]. 电气开关, 2013, 51(2): 73-75, 79. [7] 郭宏燕, 龚东武, 万煜新, 等. 变电设备状态接入控制器的Web系统[J]. 电气技术, 2016, 17(2): 32-35. [8] 陈伟根, 龙震泽, 谢波, 等. 不同气隙尺寸的油纸绝缘气隙放电特征及发展阶段识别[J]. 电工技术学报, 2016, 31(10): 49-58. [9] 滕予非, 王鱼, 焦在滨, 等. 特高压直流输电系统接地极引线阻抗监视策略[J]. 电工技术学报, 2016, 31(11): 157-164. [10] 李登. 35kV单进线变电站主变压器中性点过电压原因分析及预防措施[J]. 四川水力发电, 2013, 32(4): 142-145. [11] 许红兵, 马灿明, 包晓东. 35kV主变压器中性点避雷器的运用[J]. 供用电, 2006, 23(1): 55-57. [12] 中华人民共和国国家标准. GB/T 28547—2012 交流金属氧化物避雷器选择和使用导则[S]. |
|
|
|