Abstract High impedance fault (HIF) is difficult to detect because of the low fault current amplitude and they can be easily confused with switching events. Existing HIF detection methods mainly rely on fixed time-window data. However, a fixed decision time often fails to balance the accuracy and speed of HIF detection. Thus, a sequence-adaptive HIF detection model is proposed in this paper. Firstly, zero-sequence current data of the faulty feeder are processed into variable-length training set. Then, a gated recurrent unit (GRU) model is trained based on variable-length data and cost-sensitive coefficient method to construct biased models. Two GRU models with opposite propensities are combined into an evaluation model. The test results on the PSCAD/EMTDC simulation platform show that the detection accuracy rate of this proposed model can reach 99.13%, and the detection speed is improved by at least 37.52% compared to the fixed time-window method. Delayed decision-making improves the accuracy of HIF detection and reduces the risk of harm.
|
Received: 18 November 2024
|
|
|
|
[1] 姚福星, 苗世洪, 涂青宇, 等. 考虑强对流天气的乡镇配电网树线矛盾风险预警及优化处理[J].电工技术学报, 2023, 38(22): 6188-6203. [2] 钟逸涵, 邓丰, 史鸿飞, 等. 基于动态电阻串联的高阻接地故障精确建模[J].电工技术学报, 2024, 39(7): 2046-2059. [3] 李君, 何敏, 黄守道, 等. 基于相位差的小电阻接地有源配电网接地故障保护算法[J].电工技术学报, 2024, 39(23): 7418-7429. [4] LI Jie, LIU Yinliang, LI Chengxin, et al.An FTU-based method for locating single-phase high- impedance faults using transient zero-sequence admittance in resonant grounding systems[J].IEEE Transactions on Power Delivery, 2022, 37(2): 913-922. [5] WANG Xiaowei, GAO Jie, WEI Xiangxiang, et al.Faulty feeder detection under high impedance faults for resonant grounding distribution systems[J].IEEE Transactions on Smart Grid, 2023, 14(3): 1880-1895. [6] 唐钧益, 曾肖枫, 高伟. 一种基于经验模态分解和局部极大值点数的配电网高阻接地故障检测方法[J].电气技术, 2024, 25(6): 14-23. [7] 袁涛, 杨庆, 周桐, 等. 基于零序电流非线性畸变特性的弧光高阻接地初期故障辨识方法[J/OL].中国电机工程学报, 1-12 [2024-12-24].https://doi.org/10.13334/j.0258-8013.pcsee.232806. [8] 刘科研, 詹惠瑜, 谭云耀, 等. 基于改进极限学习机的配电网高阻接地故障检测方案[J].电网技术, 2023, 47(5): 1886-1896. [9] 王康, 高伟, 杨耿杰. 基于高频分量的配电网高阻接地故障识别[J].电气技术, 2022, 23(2): 61-66, 87. [10] ZENG Xiaofeng, GAO Wei, YANG Gengjie.High impedance fault detection in distribution network based on S-transform and average singular entropy[J].Global Energy Interconnection, 2023, 6(1): 64-80. [11] 刘炳南, 郭谋发, 陈永往. 基于KNN的配电网高阻接地故障识别[J].电气技术, 2019, 20(1): 18-23. [12] 张君琦, 杨帆, 郭谋发. 配电网高阻接地故障时频特征SVM分类识别方法[J].电气技术, 2018, 19(3): 37-43. [13] 肖启明, 郭谋发. 基于变分模态分解与图信号指标的配电网高阻接地故障识别算法[J].电气技术, 2021, 22(5): 50-55. [14] 柯亮, 李波, 廖凯, 等. 基于XGBoost的配电网高阻接地故障检测方法[J].电力系统保护与控制, 2024, 52(6): 88-98. [15] GUO Moufa, LIU Wenli, GAO Jianhong, et al.A data- enhanced high impedance fault detection method under imbalanced sample scenarios in distribution net- works[J].IEEE Transactions on Industry Applications, 2023, 59(4): 4720-4733. [16] 高伟, 何文秀, 郭谋发, 等. 基于实测不均衡小样本的配电网高阻接地故障检测方法[J/OL].高电压技术, 1-11 [2024-12-24].https://doi.org/10.13336/j.1003-6520.hve.20231972. |
|
|
|