电气技术  2018, Vol. 19 Issue (10): 59-61    DOI:
技术与应用 |
给煤机变频器低电压穿越装置的优化配置方案
刘辉
大唐华中电力试验研究院,郑州 450000
The optimizing configuration of low voltage through device in coal feeder converter
Liu Hui
Datang Central-China Electric Power Test Research Institute, Zhengzhou 450000
全文: PDF (4017 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 随着变频技术在火电厂辅机中的广泛应用,为保证机组在厂用电压跌落的情况下正常运行,辅机变频器的低电压穿越装置必不可少。本文分析了低电压穿越装置的基本原理,并提出了一种针对给煤机变频器的低电压穿越装置优化配置方案。该配置方案能够保证在厂用母线电压跌落时机组安全稳定运行,且在经济性方面要显著优于目前的方案。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
刘辉
关键词 变频器辅机给煤机低电压穿越装置优化配置    
Abstract:With the application of converter in auxiliary engine in power plant, low voltage through device is necessary to guarantees the power quality. The paper analyze the fundamental of low voltage through device, and put forward a program to solve the problem aim at coal feeder converter. The optimizing configuration program is more economical than present scheme on the premise that unit is operating stablely.
Key wordsconverter    auxiliary    coal feeder    LVRT Device    optimizing   
收稿日期: 2018-02-28      出版日期: 2018-10-23
作者简介: 刘辉(1990-),男,硕士研究生,工程师,主要从事继电保护的研究工作。
引用本文:   
刘辉. 给煤机变频器低电压穿越装置的优化配置方案[J]. 电气技术, 2018, 19(10): 59-61. Liu Hui. The optimizing configuration of low voltage through device in coal feeder converter. Electrical Engineering, 2018, 19(10): 59-61.
链接本文:  
https://dqjs.cesmedia.cn/CN/Y2018/V19/I10/59