Abstract The overheating of bolts along the high voltage reactor tank edge is one of the factors that threatens the safety of reactor operation. This paper analyzes the possible causes of overheating of bolts along the reactor tank edge. Through the analysis of an example of overheating bolts along the reactor tank edge in a substation of an offshore wind farm, the cause of overheating of bolts is correctly judged and an effective solution is put forward, which finally eliminates the problem of overheating of bolts. Finally, the treatment of problems similar to overheating bolts of a transformer's or a reactor's tank edge is summarized.
|
Received: 30 November 2020
|
|
|
|
Cite this article: |
ZHANG Shaopeng,WANG Tuanjie,GUO Pei等. Analysis and treatment of overheating of bolts along the high voltage reactor tank edge[J]. Electrical Engineering, 2021, 22(8): 55-57.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2021/V22/I8/55
|
[1] 张清伟. 并联电抗器在长距离海缆供电中的作用[J]. 化工设计通讯, 2017, 43(9): 27. [2] 带电设备红外诊断应用规范:DL/T 664—2016[S]. 2016. [3] 变压器油中溶解气体分析和判断导则:DL/T 722—2014[S]. 2014. [4] 何敏鸿. 变压器箱沿连接螺栓过热原因分析与处理[J]. 黑龙江科技信息, 2008(34): 40. [5] 陈伟博, 叶开明. 变压器器身与底座连接螺栓发热问题探讨[J]. 电工技术, 2019(9): 108-109, 118. |
|
|
|