Abstract There are a lot of reactive power and nonlinear loads in distribution network in three-phase four-wire system.It has a good effect of a low-voltage static var generator, that works under a balanced load. However, in the case of unbalanced load, the result is not so good. In this paper, a novel control method for three-level static var generator under unbalanced load in three-phase four-wire system is proposed to solve the problem. The proposed system is modeled under the Matlab/Simulink environment, simulation results show that: the strategy this paper proposed can achieve three-phase reactive-power compensation effectively in three-phase four-wire system, and has a good effect on reactive-power compensation under the unbalanced load.
|
Received: 30 July 2019
Published: 27 February 2020
|
|
|
|
Cite this article: |
Zhao Can,Gu Shuo,Huang Chao等. A novel control method for three-level static var generator under unbalanced load in three-phase four-wire system[J]. Electrical Engineering, 2020, 21(2): 31-37.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2020/V21/I2/31
|
[1] 王兆安, 杨君, 刘进军, 等. 谐波抑制和无功功率补偿[M]. 北京: 机械工业出版社, 1998. [2] 胡铭, 陈珩. 用户电力技术在配电系统的应用[J]. 电力自动化设备, 1999, 19(6): 24-26. [3] 熊桥坡, 罗安, 马伏军. 模块化多电平SVG负序补偿容量比较[J]. 中国电机工程学报, 2014, 34(24): 4049-4056. [4] 陈明锋, 雷万钧, 付翀丽, 等. T型三电平结构SVG的损耗研究[J]. 大功率变流技术, 2015(4): 56-60. [5] 池帮秀, 张茂松, 王群京, 等. 基于T型三电平变换器的SVG仿真研究[J]. 电测与仪表, 2018, 55(11): 19-24. [6] 刘勇超, 葛兴来, 冯晓云. 两电平与三电平NPC逆变器单桥臂故障重构拓扑SVPWM算法比较研究[J]. 中国电机工程学报, 2016, 36(3): 775-783. [7] 孙红星, 何德刚, 吴文波. 基于链式SVG三相不平衡负荷的平衡补偿方法的仿真分析[J]. 自动化技术与应用, 2014, 33(6): 60-64. [8] 辛业春, 李国庆, 王朝斌. 无功和三相负荷不平衡的序分量法补偿控制[J]. 电力系统保护与控制, 2014, 42(14): 72-78. [9] 杨朝强, 付子义, 董彦杰. 不平衡电网下的无功补偿控制策略[J]. 软件, 2018, 39(11): 96-100. [10] 王跃, 杨昆, 陈国柱. 级联DSTATCOM补偿不平衡负载分相控制策略[J]. 电力自动化设备, 2015, 35(5): 23-28, 50. [11] Luo Rui, He Yingjie, Liu Jinjun.Research on the unbalanced compensation of delta-connected cascaded H-bridge multilevel SVG[J]. IEEE Transactions on Industrial Electronics, 2018, 65(11): 8667-8676. [12] 刘云潺, 黄纯, 欧立权, 等. 基于dq变换的三相不平衡电压暂降检测方法[J]. 电力系统及其自动化学报, 2007, 19(3): 72-76. [13] 温华生, 谢潮. 基于dq变换的三相自适应锁相环技术[J]. 上海电力学院学报, 2016, 32(2): 151-155. [14] 孙孝峰, 钨伟扬. 基于瞬时无功理论电压不平衡三相变流器控制研究[C]//中国电工技术学会电力电子学会第八届学术年会论文集, 2002: 561-565. [15] 任明炜, 孙玉坤, 郑红平. 单相电路的谐波和基波无功检测新方法[J]. 中国农村水利水电, 2005(5): 115-117, 119. |
|
|
|