电气技术  2014, Vol. 15 Issue (06): 10-14    DOI:
研究与开发 |
含隔离式断路器的新一代智能变电站主接线可靠性评估及灵敏度分析
黄扬琪,路欣怡,刘念,张建华
华北电力大学电气与电子工程学院,北京 102206
Analysis on Reliability and Sensitivity of Main Electrical Connection for New Generation Smart Substation with Disconnecting Circuit Breaker
Huang Yangqi, Lu Xinyi, Liu Nian, Zhang Jianhua
School of Electrical and Electronic Engineering, North China Electric Power University, Beijing 102206
全文: PDF (691 KB)   HTML (0 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 随着国家电网公司智能变电站建设的不断推进,提出了基于新型设备研制的新一代智能变电站主接线整体集成设计理念,从而实现电气主接线可靠性水平的提高和接线形式的优化。本文结合新型集成设备隔离式断路器的特点及其在主接线中的应用情况,基于邻接终点矩阵的最小割集算法,对采用常规断路器的双母线接线和采用隔离式断路器的单母线分段和双母线接线进行可靠性评估,同时对隔离式断路器的各项可靠性参数进行灵敏度分析。结果表明:隔离式断路器的使用能有效提高主接线的可靠性水平,同时简化接线形式,并且该设备的强迫故障率和计划检修停运时间两个参数对整个主接线可靠性影响较大。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
黄扬琪
路欣怡
刘念
张建华
关键词 智能变电站隔离式断路器最小割集可靠性灵敏度    
Abstract:With the continuous deepening of smart substation construction in State Grid Corporation, the overall integration design concept of the new generation smart substation based on research and development of new equipment is put forward, realizing the main electrical connection optimization and improvement of reliability. Concerning the characteristic and application of disconnecting circuit breaker in smart substation, reliability of double bus connection with conventional circuit breaker, single bus with two sections and double bus connection with disconnecting circuit breaker is evaluated by the minimal cut-set method based on adjacency matrix of end in this paper. Moreover, the sensitivity analysis on the reliability parameters of disconnecting circuit breaker is emphatically contrasted. Comparison results show that reliability of the main electrical connection can be greatly improved with disconnecting circuit breaker and the impact of forced failure rate and scheduled maintenance outage time of that equipment on system reliability is greater.
Key wordssmart substation    disconnecting circuit breaker (DCB)    minimal cut-set    reliability    sensitivity   
     出版日期: 2014-06-11
基金资助:国家电网公司科技项目资助(JSB17201200329)
作者简介: 黄扬琪(1991-),女,硕士,研究方向为智能变电站。
引用本文:   
黄扬琪,路欣怡,刘念,张建华. 含隔离式断路器的新一代智能变电站主接线可靠性评估及灵敏度分析[J]. 电气技术, 2014, 15(06): 10-14. Huang Yangqi, Lu Xinyi, Liu Nian, Zhang Jianhua. Analysis on Reliability and Sensitivity of Main Electrical Connection for New Generation Smart Substation with Disconnecting Circuit Breaker. Electrical Engineering, 2014, 15(06): 10-14.